您現(xiàn)在的位置: > 燃燒機(jī)配件 |
|
西門子SKP50...系列燃?xì)忾y門執(zhí)行器 |
SKP50...系列燃?xì)忾y門執(zhí)行器
品牌:SIEMENS(西門子)
產(chǎn)地:德國 |
產(chǎn)品介紹 |
The SKP50... controls the differential pressure in the gas supply line in function of the differential pressure in the supply air duct.
The air / gas volume ratio thus remains constant regardless of air volume changes.
The SKP50... also provides the functions of a safety shutoff valve to EN 161 when used in connection with Landis & Staefa gas valves type VG...
Control of the air / gas volume ratio on multi-stage or modulating gas burners with a central or decentral air supply.
Major fields of use:
-
In burner plants with integrated heat recovery systems
-
On burners with an adjustable air / gas mixing facility in the burner head
-
In plants where, in the case of load changes, the pressure conditions in the burner and in the combustion chamber do not change in a linear fashion
In plants with negative pressures on the gas or air side
With the SKP50... - in contrast to conventional compound control - air volume variations caused by
-
mains voltage fluctuations
-
dirty fan wheels
-
changes in the combustion chamber pressure
-
associated heat recovery systems
have no impact on the quality of the combustion process.
When using the SKP50..., a separate gas pressure governor is not required. Since the integrated gas pressure controller does not cause any additional pressure losses, a smaller valve size than usual can be chosen on most applications. The usual measures required for ensuring the minimum air volume must also be taken when using the SKP50....
|
型號(hào)表 |
|
|
沒有輔助終端 |
有輔助終端 |
AC220...240V |
不帶輔助開關(guān) |
SKP50.110C27 |
- |
帶輔助開關(guān) |
SKP50.111C27 |
SKP50.111C27R |
AC100...110V |
帶輔助開關(guān) |
SKP50.111C17 |
SKP50.111C17R | |
技術(shù)參數(shù) |
主要參數(shù) |
主要電壓 |
AC220V -15%...AC240V +10% |
|
AC100V -15%...AC110V +10% |
主頻率 |
50...60Hz ±6% |
功率 |
9...13VA |
輔助開關(guān) |
6A,AC250V |
輔助開關(guān)設(shè)置范圍 |
4...96% |
全部開啟時(shí)間 |
6...12s |
關(guān)閉時(shí)間 |
<1s |
負(fù)荷從大轉(zhuǎn)小時(shí)的最小時(shí)間 |
5s |
允許測(cè)試壓力(燃?xì)猓?/FONT> |
1bar |
允許運(yùn)行壓力(燃?xì)猓?/FONT> |
200mbar |
保護(hù)等級(jí) |
IP54 |
重量 |
1750g | | |
環(huán)境條件 |
運(yùn)輸環(huán)境 |
IEC 721-3-2 |
內(nèi)部條件 |
class 2K2 |
機(jī)械條件 |
class 2M2 |
溫度范圍 |
-40...+60ºC |
濕度 |
<95% |
運(yùn)行環(huán)境 |
IEC 721-3-3 |
內(nèi)部條件 |
class 3K5 |
機(jī)械條件 |
class3M2 |
溫度范圍 |
-15...+60ºC(低于0ºC,打開時(shí)間增加) |
濕度 |
<95% |
不得進(jìn)水 | | | |
|